Mitsubishi Electric MELSEC-QD75MH1 User Manual page 537

Positioning module
Table of Contents

Advertisement

11 MANUAL CONTROL
MELSEC-Q
Creating the program
— á
Example
No. 10 JOG operation setting program
<Set JOG operation speed (100.00mm/min)>
<Set a "0" for inching movement amount>
<Write JOG operation speed>
No.12 JOG operation/inching operation execution program
<JOG/inching operation flag ON>
<JOG/inching operation termination>
<Execute forward JOG/inching operation>
<Execute reverse JOG operation>
11 - 12