15 TROUBLESHOOTING
Classification
Error
of errors
code
Backlash
920
compensation
amount error
Software stroke limit
921
upper limit
Software stroke limit
922
under lower limit
Software stroke limit
Parameter
923
selection error
setting range
errors
Software stroke limit
924
valid/invalid setting
error
Command
925
in-position width
error
Illegal torque limit
926
setting value error
M code ON timing
927
error
Speed switching
928
mode error
Interpolation speed
929
designation method
error
Current value update
930
request error
Manual pulse
932
generator input
mode error
Error name
The calculation result of the following
equation is smaller than 0 or larger than
65536.
0 ≤
• In the unit of degree, the set value of
the detailed parameter 1 "Software
stroke limit upper limit value" is
outside the setting range.
• In a unit other than degree, the
software stroke limit upper limit value
is smaller than the software stroke
limit lower limit value.
• In case unit is "degree", the set range
of the detailed parameter 1 "Software
stroke limit lower limit value" is outside
the setting range.
• In case unit is different than "degree",
the software stroke limit upper limit
value is smaller than the software
stroke limit lower limit value.
The set range of the detailed parameter
1 "Software stroke limit selection" is
outside the setting range.
The set range of the detailed parameter
1 "Software stroke limit valid/invalid
setting" is outside the setting range.
The set range of the detailed parameter
1 "Command in-position width" is
outside the setting range.
The set range of the detailed parameter
1 "Torque limit setting value" is outside
the setting range.
The set range of the detailed parameter 1
"M code ON signal output timing" is
outside the setting range.
The set range of the detailed parameter
1 "Speed switching mode" is outside
the setting range.
The set range of the detailed parameter
1 "Interpolation speed designation
method" is outside the setting range.
The set range of the detailed parameter
1 "Current feed value during speed
control" is outside the setting range.
The set range of the detailed parameter
1 "Manual pulse generator input
selection" is outside the setting range.
Error
Pr.11
Pr.2
≤ 65535
Pr.3
15 - 26
MELSEC-Q
Operation status at error
occurrence
The QD75 READY signal (X0) is
not turned ON.
The QD75 READY signal (X0) is
not turned ON.