ABB ACS560 Quick Installation And Start-Up Manual page 97

Hide thumbs Also See for ACS560:
Table of Contents

Advertisement

Drive type
Minimum
ACS560-
short cir-
cuit cur-
rent 1)
A
039A-4
170
046A-4
280
062A-4
380
073A-4
480
088A-4
480
106A-4
700
145A-4
1000
169A-4
1280
206A-4
1520
246A-4
2050
293A-4
2200
1) minimum short-circuit current of the device
Input cur-
rent
Rated cur-
rent I
N
A
A
38.0
63
45.0
80
62
100
73
125
88
160
106
200
145
250
169
315
206
350
246
450
293
500
gG (IEC 60269)
2
I
t
Rated
ABB desig-
voltage
nation type
2
A
s
V
1450
690
170M1565
2550
690
170M1566
4650
690
170M1567
8500
690
170M1568
16000
690
170M1569
15000
690
170M3815
28500
690
170M3816
46500
690
170M3817
68500
690
170M3818
105000
690
170M5809
145000
690
170M5810
Technical data 97
IEC 60269
size
000
000
000
000
000
EN
1
HI
1
1
1
2
2

Hide quick links: