Mitsubishi Electric Fatec GOT2000 Series Basic Training Textbook page 246

Graphic operation terminal
Hide thumbs Also See for Fatec GOT2000 Series:
Table of Contents

Advertisement

E
Edge trigger
A trigger that updates the data display when the rising or falling edge of the specified bit is detected. Even if the
trigger is not generated, the data can be forcibly displayed ON at the first time after the screen is switched.
Edit Vertex
This is an editing function for changing the position of vertices of polygons or consecutive straight lines after
drawing.
EN Standard
Indicates a product that conforms with EC directives.
The EN Standard is one standard in EC directives (laws).
There are three main relevant EC directives: EMC directives, low-voltage directives, and mechanical directives.
The EN Standard is the standard used for products meeting these directives. (example safety)
Ethernet connection
This is a connection method using typical network standards for personal computers.
A PLC and a GOT are connected using the Ethernet cable.
Extended system application
Application that is required for using some functions, such as the system monitor function and the logging
function.
Extension cable
This cable connects the PLC extension base (basic base) and the GOT when the PLC and GOT are connected
with a bus connection.
Extension file register (R)
These are file register extension registers in the PLC memory cassette.
The extension file register capacity is set with parameters.
The capacity that can be set depends on the CPU used and the memory cassette capacity.
Indicated with R with MELSEC-A.
Indicated with R and ZR with MELSEC-QnA.
Indicated with R and ZR with MELSEC-QnU.
F
Falling (trigger)
This is the status when the devices goes from ON to OFF.
With a GOT, the condition established just once at the fall is called a falling trigger.
Be aware that after the device falls, if the time until it comes ON is short, sometimes the fall cannot be detected
and display is not possible.
When [Display objects immediately after the screen is switched regardless of display conditions] is selected, data
can be displayed even if the trigger condition is not satisfied when the screen is switched.
File register (R)
These are extension registers for when data registers (D) are insufficient.
The file register capacity is set with parameters.
The capacity that can be set depends on the CPU used and the memory cassette capacity.
Free location touch switch
Free location touch switches are so called because they are touch switches with a minimum of 2-by-2 dots, and
they can be located freely per dot.
The enabled/disabled area can be specified and the switch can also be protected conditionally.
G
Graphic operation terminal
The name of the Mitsubishi Electric display unit.
The name GOT is an acronym for Graphic Operation Terminal.
App - 62