P-35 Main Reactance (Xh)
Range:
100.0000
[1.0000 - 10000.0000 Ohm]
Ohm*
P-36 Iron Loss Resistance (Rfe)
Range:
10000.000
[0 - 10000.000 Ohm]
Ohm*
P-37 d-axis Inductance (Ld)
Range:
0 mH*
[0 - 0.000 mH]
Function:
Set the main reactance of the motor using one of these methods:
1.
Run an Auto Tune on a cold motor. The frequency converter will measure the value from the
motor.
2.
Enter the X
value manually. Obtain the value from the motor supplier.
h
3.
Use the X
default setting. The frequency converter establishes the setting on the basis of the
h
motor name plate data.
Function:
Enter the equivalent iron loss resistance (R
The R
value cannot be found by performing an Auto Tune.
Fe
The R
value is especially important in torque control applications. If R
Fe
Loss Resistance (Rfe) on default setting.
Function:
Enter the value of the d-axis inductance. Obtain the value from the permanent magnet motor data sheet.
The d-axis inductance cannot be found by performing an Auto Tune.
AF-650 GP Programming Guide
) value to compensate for iron loss in the motor.
Fe
is unknown, leave par. P-36 Iron
Fe
3
87