GE AF-650 GP Programming Manual page 145

General purpose drive
Hide thumbs Also See for AF-650 GP:
Table of Contents

Advertisement

DR-40 Trending Buffer Full
Option:
[0] *
No
[1]
Yes
3
3.17.4 DR-5# Ref. & Feedb.
Parameters to view the reference and feedback status values.
DR-50 External Reference
Range:
0.0*
[-200.0 - 200.0]
DR-51 Pulse Reference
Range:
0.0*
[-200.0 - 200.0]
DR-52 Feedback [Unit]
Range:
0.0*
[-999999.999 - 999999.999]
DR-53 Digi Pot Reference
Range:
0.0*
[-200.00 - 200.00]
144
Function:
View whether the logging buffer is full (see par. ID-1#). The logging buffer will never be full when par.
ID-13 Trending Mode is set to Log always [0].
Function:
View the total reference, the sum of digital, analog, preset, bus and freeze references, plus catch-up and
slow-down.
Function:
View the reference value from programmed digital input(s). The read-out can also reflect the impulses
from an incremental encoder.
Function:
View the feedback unit resulting from the selection of unit and scaling in par. F-50 Reference Range, par.
F-51 Reference/Feedback Unit, par. F-52 Minimum Reference and par. F-53 Maximum Reference.
Function:
View the contribution of the Digital Potentiometer to the actual reference.
AF-650 GP Programming Guide