Connecting The Manual Pulse Generator - Mitsubishi Electric C80 Series Connection And Set Up Manual

Hide thumbs Also See for C80 Series:
Table of Contents

Advertisement

C80 Series Connection and Setup Manual
6 Wiring and Connecting

6.9 Connecting the Manual Pulse Generator

Connect the signals of manual pulse generator(s) to any of the following connectors.
- Connector MPG or EXT I/F on CNC CPU module
- Connector MPG on signal splitter (FCU7-HN387)
All of the connectors above allow the connection of 5V power supply type manual pulse generator (UFO-01-2Z9).
The connector MPG on signal splitter allows the connection of 12V power supply type manual pulse generator (HD60C)
as well.
(Note) Set the parameter shown below to suit the manual pulse generator used.
- 5V manual pulse generator (UFO-01-2Z9): #1240 set12/bit0 = 1 (100 pulse/rev)
- 12V manual pulse generator (HD60C): #1240 set12/bit0 = 0 (25 pulse/rev)
IB-1501452-C
84

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents