10 PLC CPU Initial Setup
(6) When connecting two units of CNC CPU, perform the following setting.
(a) Set <Detailed Setting> under "Memory/Device setting" - "Device/Label Memory Area Setting" - "Device/Label
Memory Area Detailed Setting" - "Device Setting".
Link relay B: "24" (24K Word)
(7) When connecting three units of CNC CPU, perform the following setting.
(a) Set "Device/Label Memory Area Capacity Setting" under "CPU Parameter" - "Memory/Device Setting" -
"Device/Label Memory Area Setting".
Device Area Capacity under "Device Area": "48" (48K Word)
File Storage Area Capacity under "Label Area": "120" (120K Word)
(b) Set <Detailed Setting> under "Memory/Device setting" - "Device/Label Memory Area Setting" - "Device/Label
Memory Area Detailed Setting" - "Device Setting".
Link relay B: "32" (32K Word)
Data register D: "26" (26K Word)