Precautions - Mitsubishi Electric C80 Series Connection And Set Up Manual

Hide thumbs Also See for C80 Series:
Table of Contents

Advertisement

C80 Series Connection and Setup Manual
15 Setting the Tool Entry Prohibited Range

15.2.9 Precautions

(1) If the maximum value and minimum value of the stored stroke limit's prohibited range are set to the same value, the
following will occur.
(a) When the maximum value and minimum value are set to "0", if the outside is the prohibited range, the entire
range will be prohibited. If the inside is the prohibited range, the entire range will be the moveable range.
(b) If data other than 0 is set for the maximum value and minimum value, the entire range will be the moveable
range.
(2) The stored stroke limit IC is valid when the axis parameter #2063 is changed. If changed during automatic
operation, the function will be validated after the smoothing for all axes reaches 0.
(3) Make sure that the lower limit value of the stored stroke limit IC setting value is "smaller than the upper limit value".
(4) To set the inside of the specified range as a prohibited range, set the parameters as follow:
EX. There are 2 methods to set 10° to 70° as a prohibited range.
(Method 1) #2013 OT-: 70° #2014 OT+: 370°
(Method 2) #2013 OT-: 370°#2014 OT+: 70°