Machine End Stopper Method: Manual Initialization - Mitsubishi Electric C80 Series Connection And Set Up Manual

Hide thumbs Also See for C80 Series:
Table of Contents

Advertisement

C80 Series Connection and Setup Manual
14 Setting the Position Detection System

14.1.4 Machine End Stopper Method: Manual Initialization

(1)
Preparations
Set the parameters on the
[Abs.Posit.Param.] screen.
(2)
Turn the power OFF and ON.
(Only when "#2049 type" has been reset.)
The following are the operations on [Absolute position setting screen].(Select [Mainte] -> [To Abs pos])
(3)
Select the axis set to type 1 on the
[Abs.Posit.Param.] screen.
Select the menu [Axis select], enter
the axis name (#1022 axname2
(display axis name)) in the input area
and then press [INPUT].
(4)
Select "HANDLE" or "JOG" for the
mode selection of machine operation
switch.
(5)
Confirm that the cursor is placed on
"Absolute posn set", input "1" in the
input area and press the [INPUT] key.
#2049 type (absolute position detection type) = 1 (stopper method)
#2054 clpush (current limit) = 0 to 100
#2059 zerbas (select zero point parameter and basic point) =0
(position where the axis was stopped) *1
The parameters other than "#2049 type" can also be set on [Absolute
position setting screen].
The input value is registered in the "Absolute posn set" area.