4 General Specifications
For the specifications of GOT, I/O unit, etc. refer to the manuals listed in "List of Configuration".
For the drive unit specifications, refer to the specification manual for the drive unit you are using

4.1 Installation Environment Conditions

C80, which is an open equipment, must be installed within a sealed metal control panel (IP54 or higher).
C80 must also be used and stored under the conditions listed in the table of specifications below.
Item
Operating ambient
temperature
Storage ambient
temperature
Operating ambient
humidity
Storage ambient humidity
Compliant
with JIS B
Vibration resistance
3502 and
IEC 61131-2
Shock resistance
Operating ambience
Operating altitude
Installation location
Overvoltage category
(Note 1)
Pollution level (Note 2)
(Note 1) This indicates the section of the power supply to which the equipment is assumed to be connected between the
public electrical power distribution network and the machinery within premises.
Category II applies to equipment for which electrical power is supplied from fixed facilities.
The surge withstand voltage for the equipment up to the rated 300V is 2500V.
(Note 2) This index indicates the degree to which conductive material is generated in terms of the environment in which
the equipment is used.
Pollution level 2 is when only non-conductive pollution occurs. A temporary conductivity caused by condensing
must be expected occasionally.
(Note 3) Do not use or store C80 under pressure higher than the atmospheric pressure of altitude 0m. Doing so can
cause an operation failure.
(Note 4) The following environment conditions are also required for the layout design.
・No large amount of conductible dust, iron filings, oil mist, salt, or organic solvents
・No direct sunlight
・No strong electrical or magnetic fields
・No direct vibrations nor shocks on C80
IB-1501452-C
0 to 55 ℃ (-13 to 167°F)
-25 to 75 ℃ (-13 to 167°F)
5 to 95%RH non-condensing
5 to 95%RH non-condensing
Frequency
Under
5 to 8.4Hz
intermittent
8.4 to 150Hz
vibration
Under
5 to 8.4Hz
continuous
8.4 to 150Hz
vibration
2
147m/s
, 3 times in each of 3 directions X, Y, Z
No corrosive gases nor inflammable gases
2000m (6561.68ft.) or less (Note 3)
Inside control panel
24
Specification
Constant
Half amplitude
acceleration
-
3.5mm
2
-
9.8m/s
-
1.75mm
2
-
4.9m/s
II or less
2 or less
Sweep count
10 times each in X, Y,
Z directions (For 80
min.)
-