6 Wiring and Connecting
(1) Connecting directly to CNC CPU module
Connect signals from manual pulse generator(s) to the connector MPG.
The connector EXT I/F is applied when the channel 2 and 3 are used.
5V power supply type is available as of manual pulse generator.
When connecting a 5V manual pulse generator
R16NCCPU
(Bottom view)
MPG
When connecting two 5V manual pulse generators
R16NCCPU
(Note) Channel 2 and 3 are uned in this wiring example. H300 cable is a composite cable with skip signal.
<Related items>
Cable drawing: "Cable: H401 Cable, H300 Cable"
(Note 1) When selecting a manual pulse generator, make sure that its case and 0V terminal are insulated.
(Note 2) When connecting cables using a terminal block, etc., never fail to observe the followings.
- The total length of the cables from the connector on C80's side to the terminal area of manual pulse
generators has to be within the maximum cable length (20m).
- Have the cable shield single-point-grounded on C80's side, and cover the cable with the shield up to
near the manual pulse generators. (It is required to relay the shield also.)
- For relay cables, use wire material of cross section equivalent to UL1061-2464 AWG26 x 2P or above.
H401
EXT I/F
H300
5V manual pulse generator
(Rear view)
NO.1
5V 0V A B
5V manual pulse generators
NO.2
5V 0V A B
To be prepared
by user
Terminal
block
85