16 Setting the Deceleration Check
(3) Designation of in-position check width
(a) Servo parameter
#
Item
SV024
In-position
2224
INP
detection width
SP024
13024
In-position width
INP
(b) Axis specification parameter
#
Item
G0
2077
G0inps
in-position width
G1
2078
G1inps
in-position width
IB-1501452-C
Details
Set the in-position detection width.
Set the accuracy required for the machine.
The lower the setting is, the higher the positioning
accuracy gets; however, the cycle time (setting time)
becomes longer.
The standard setting value is "50".
Set the in-position detection width.
Set the positioning accuracy required to the machine.
Lower setting value increases the positioning accuracy,
but prolongs the cycle time (settling time).
The standard setting is "875".
Details
Set the in-position width for G0.
Between SV024 and this parameter, the parameter with
a larger value will be applied.
When "0" is set, this parameter will be invalid: only
SV024 will be available.
Set the in-position width for G1.
Between SV024 and this parameter, the parameter with
a larger value will be applied.
When "0" is set, this parameter will be invalid: only
SV024 will be available.
230
Setting range
0 to 32767 (μm)
0 to 32767
(1deg/1000)
Setting range
0.000 to 99.999 (mm)
0.000 to 99.999 (mm)