Setup and Installation
2
Model S30817-Q936-C282
2.1 Settings
Considerations
216
J1
ON: Works as a pager
OFF: Works as an Entrance Telephone.
J2
ON: Disables the timeout for paging.
OFF: Enables a 15-second timeout for paging.
J3 to J8
Not used
The wiring connecting the X2 connector to the PABX must have a max-
imum length of 32.8 feet (10 meters)
For information on the length of wiring between the X6 connector and
the Entrance Telephone (at the street) see the manufacturer's specifi-
cations. This interface supports HDL 's brand Entrance Telephones
(F5AZ, F8AZ and F9AZ).
In Pager Mode the X4 connector is connected to an audio output, and
the X5 connector to an audio input.