Mitsubishi Electric FR-A820-00046 Instruction Manual page 557

Fr-a800 series
Hide thumbs Also See for FR-A820-00046:
Table of Contents

Advertisement

Parameters
Hiding the decimal places for the monitors (Pr. 268)
The numerical figures after a decimal point displayed on the operation panel may fluctuate during
analog input, etc. The decimal places can be hidden by selecting the decimal digits with Pr. 268.
Pr. 268 setting
9999 (initial value)
Tab. 5-135: Selection of decimal digits
NOTE
The number of display digits on the cumulative energization time (Pr. 52 = "20"), actual operation
time (Pr. 52 = "23"), cumulative power (Pr. 52 = "25") and cumulative energy saving (Pr. 52 = "51")
does not change.
Minus sign display for the monitors (Pr. 290)
A negative output can be selected for the monitor display of the terminal AM (analog voltage output),
the operation panel, and a communication option. For a list of the monitors that can output values
with minus signs, refer to the monitor description list (on page 5-345).
Pr. 290 setting
0 (initial value)
⎯: Output without minus sign (positive values only)
Tab. 5-136: Minus sign display for the monitors
FR-A800
Description
No function
For the first or second decimal places (0.1 increments or 0.01 increments) of the monitor, numbers in
0
the first decimal place and smaller are rounded to display an integral value (1 increments). The
monitor value equal to or smaller than 0.99 is displayed as 0.
When monitoring with the second decimal place (0.01 increments), the 0.01 decimal place is
1
dropped and the monitor displays the first decimal place (0.1 increments). When monitoring with
the first decimal place, the display will not change.
Terminal AM output
1
Output with a minus sign
2
3
Output with a minus sign
4
5
Output with a minus sign
6
7
Output with a minus sign
(M) Monitor display and monitor output signal
Operation panel display
Displayed with minus sign.
Displayed with minus sign.
Output with a minus sign
Output with a minus sign
Monitoring via
communication
Output with a minus sign
Output with a minus sign
Output with a minus sign
Output with a minus sign
5 - 355

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents