Installation and wiring
2.11

Wiring for use of the CC-Link IE Field Network (FR-A800-GF)

2.11.1

System configuration example

● Mount the "RJ71EN71", "RJ71GF11-T2", "QJ71GF11-T2", or "LJ71GF11-T2" type CC-Link IE Field
Network master/local module on the main or extension base unit having the programmable
controller CPU used as the master station.
● Connect the CC-Link IE Field Network programmable controller (master station) to the inverter
with an Ethernet cable.
Fig. 2-74:
NOTE
Refer to the instruction manuals regarding the CC-Link IE Field Network master station:
● RJ71EN71 type, RJ71GF11-T2 type:
MELSEC iQ-R CC-Link IE Field Network User's Manual (Application)
● QJ71GF11-T2 type:
MELSEC-Q CC-Link IE Field Network Master/Local Module User's Manual
● LJ71GF11-T2 type:
MELSEC-L CC-Link IE Field Network Master/Local Module User's Manual
FR-A800
Master station
QJ71GF11-T2
Power supply
Ethernet cable
CC-Link IE Field Network System configuration
Wiring for use of the CC-Link IE Field Network (FR-A800-GF)
Intelligent device station
Inverter
Up to 120 units
can be
connected
Motor
Power supply
Inverter
Motor
I003072E
2 - 103