Mitsubishi Electric FR-A820-00046 Instruction Manual page 104

Fr-a800 series
Hide thumbs Also See for FR-A820-00046:
Table of Contents

Advertisement

Connection of motor with encoder (vector control)
● Motor and switch setting
Motor
Mitsubishi standard motor with
encoder
Mitsubishi high-efficiency motor with
encoder
Mitsubishi constant-torque motor
with encoder
Vector control dedicated motor
Other manufacturer's motor with encoder
Tab. 2-32:
Set according to the motor (encoder).
Prepare an encoder's power supply (5 V/12 V/15 V/24 V) according to the encoder's output voltage.
When the encoder output is the differential line driver type, only 5 V can be input.
NOTE
The SW2 switch is for manufacturer setting. Do not change the setting.
● Encoder specification
Item
Resolution
Power supply voltage
Current consumption
Output signal form
Output circuit
Output voltage
Tab. 2-33:
2 - 74
SF-JR
SF-HR
Other
SF-JRCA
SF-HRCA
Other
SF-V5RU
Motor used and switch setting
Encoder for SF-JR
1024 pulses/rev
5 V DC ±10%
150 mA
A, B phases (90° phase shift)
Z phase: 1 pulse/rev
Differential line driver 74LS113 equivalent
H level: 2.4 V or more
L level: 0.5 V or less
Encoder specification
Encoder type selection
Terminating resistor
switch (SW3)
selection switch (SW1)
Differential
Differential
Differential
Differential
Complementary
Encoder for SF-V5RU
2048 pulses/rev
12 V DC ±10%
150 mA
A, B phases (90° phase shift)
Z phase: 1 pulse/rev
Complementary
H level: (Power supply for encoder-3V) or more
L level: 3 V or less
Installation and wiring
Power supply
specification
ON
5 V
ON
5 V
ON
5 V
ON
5 V
OFF
12 V

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents