Parameters
Differ according to capacities.
6%: FR-A820-00077(0.75K) or lower, FR-A840-00038(0.75K) or lower
4%: FR-A820-00105(1.5K) to FR-A820-00250(3.7K), FR-A840-00052(1.5K) to FR-A840-00126(3.7K)
3%: FR-A820-00340(5.5K), FR-A820-00490(7.5K), FR-A840-00170(5.5K), FR-A840-00250(7.5K)
2%: FR-A820-00630(11K) to FR-A820-03160(55K), FR-A840-00310(11K) to FR-A840-01800(55K)
1%: FR-A820-03800(75K) or higher, FR-A840-02160(75K) or higher
The setting range or initial value for the FR-A820-03160(55K) or lower and FR-A840-01800(55K) or
lower.
The setting range or initial value for the FR-A820-03800(75K) or higher and FR-A840-02160(75K)
or higher.
The initial value for the FR-A820-00490(7.5K) or lower and FR-A840-00250(7.5K) or lower.
The initial value for the FR-A820-00630(11K) or higher and FR-A840-00310(11K) or higher.
Differ according to capacities.
4%: FR-A820-00490(7.5K) or lower, FR-A840-00250(7.5K) or lower
2%: FR-A820-00630(11K) to FR-A820-03160(55K), FR-A840-00310(11K) to FR-A840-01800(55K)
1%: FR-A820-03800(75K) or higher, FR-A840-02160(75K) or higher
The value for the 200 V class.
The value for the 400 V class.
Setting can be made only when a vector control compatible option is installed.
The setting is available only when the FR-A8AP is installed.
The setting is available only when the FR-A8AP or the FR-A8APR is installed.
The setting is available only when the FR-A8TP is installed.
The setting is available only when the FR-A8AP or the FR-A8TP is installed.
The parameter number in parentheses is the one for use with the LCD operation panel (FR-LU08)
and the parameter unit (FR-PU07).
The setting range or initial value for the standard model.
The setting range or initial value for the separated converter type.
The setting range or initial value for the IP55 compatible model.
The setting is available for the standard model only.
The setting is available only for standard models and IP55 compatible models.
The setting is available only with the 400 V class.
BK
The setting is available only with the 200 V class.
BL
The setting is available only for the FR-A800-GF or when a compatible plug-in option is installed.
BM
The setting is available for the FR-A800-E or when a compatible plug-in option is installed.