(C) Motor constant parameters
Changing the motor constant (if setting motor constants in units of [Ω], [mH] or [A])
● Set Pr. 71 as shown below.
Motor
IPM motor
SPM motor
Tab. 5-196: Motor selection
● Set a given value as the motor constant parameter.
First Pr.
90
92
93
706
1412
859
Tab. 5-197: Parameter setting ranges
For the FR-A820-03160(55K) or lower and FR-A840-01800(55K)or lower.
For the FR-A820-03800(75K) or higher and FR-A840-02160(75K)or higher.
● For PM motors, set Pr. 1412 or Pr. 1413 to set a motor induced voltage constant (phi f ) exceeding
the setting range, 0 to 5000 mV (rad/s), of Pr. 706 or Pr. 738.
To set the induced voltage constant (phi f ) set a value in the exponent n in the formula:
Pr. 706 (Pr. 738) × 10
● When Pr. 71 (Pr. 450) = "8093, 8094, 9093, or 9094", or Pr. 1412 (Pr. 1413) = "9999", the motor induced
voltage constant is as set in Pr. 706 (Pr. 738). (No exponent setting)
NOTE
Setting "9999" disables the tuning data. The MM-CF constant is used for the IPM motor MM-CF,
and the inverter internal constant is used for a PM motor other than MM-CF.
5 - 480
MM-CF
Other than MM-CF
Second Pr.
Name
458
Motor constant (R1)
Motor constant (L1)/
460
d-axis inductance (Ld)
Motor constant (L2)/
461
q-axis inductance (Lq)
Induced voltage constant
738
(phi f )
Motor induced voltage
1413
constant (phi f ) exponent
Torque current/Rated PM
860
motor current
n
[mV/(rad/s)].
Setting range
0 to 50 Ω, 9999
0 to 400 mΩ, 9999
0 to 500 mH, 9999
0 to 50 mH, 9999
0 to 500 mH, 9999 s
0 to 50 mH, 9999
0 to 5000 mV/(rad/s), 9999
0 to 2, 9999
0 to 500 A, 9999
0 to 3600 A, 9999
Parameters
Pr. 71 setting
330
8090
9090
Setting
Initial value
increments
0.001 Ω
0.01 mΩ
0.01 mH
0.001 mH
0.01 mH
9999
0.001 mH
0.1 mV/(rad/s)
1
0.01 A
0.1 A