Mitsubishi Electric FR-A820-00046 Instruction Manual page 219

Fr-a800 series
Hide thumbs Also See for FR-A820-00046:
Table of Contents

Advertisement

Parameters
Pr.
Pr.
Name
group
Communication error execution
BL
N011
500
waiting time
Communication error occurrence count
BL
N012
501
display
Stop mode selection at communication
502
N013
error
503
E710
Maintenance timer 1
Maintenance timer 1 warning output
504
E711
set time
505
M001
Speed setting reference
516
F400
S-pattern time at a start of acceleration
S-pattern time at a completion of
517
F401
acceleration
518
F402
S-pattern time at a start of deceleration
S-pattern time at a completion of
519
F403
deceleration
522
G105
Output stop frequency
Modbus® RTU communication check
539
N002
time interval
BL BM
N100
Frequency command sign selection
541
BM
N103
CC-Link extended setting
544
547
N040
USB communication station number
USB communication check time
548
N041
interval
549
N000
Protocol selection
NET mode operation command source
550
D012
selection
PU mode operation command source
551
D013
selection
552
H429
Frequency jump range
553
A603
PID deviation limit
554
A604
PID signal operation selection
555
E720
Current average time
556
E721
Data output mask time
Current average value monitor signal
557
E722
output reference current
560
A712
Second frequency search gain
561
H020
PTC thermistor protection level
563
M021
Energization time carrying-over times
564
M031
Operating time carrying-over times
Second motor excitation current break
565
G301
point
Second motor excitation current low-
566
G302
speed scaling factor
569
G942
Second motor speed control gain
570
E301
Multiple rating setting
571
F103
Holding time at a start
Tab. 5-2:
Parameter overview (by number) (16)
FR-A800
Minimum
Setting range
setting
increments
0 to 999.8 s
0.1 s
0
0 to 4
0 (1 to 9998)
0 to 9998, 9999
1 to 590 Hz
0.01 Hz
0.1 to 2.5 s
0.1 s
0.1 to 2.5 s
0.1 s
0.1 to 2.5 s
0.1 s
0.1 to 2.5 s
0.1 s
0 to 590 Hz, 9999
0.01 Hz
0 to 999.8 s, 9999
0.1 s
0, 1
0, 1, 12, 14, 18, 24, 28,
100, 112, 114, 118, 128
0 to 31
0 to 999.8 s, 9999
0.1 s
0, 1
BM
0, 1, 5
, 9999
BM
1 to 3, 5
, 9999
0 to 30 Hz, 9999
0.01 Hz
0.0 to 100%, 9999
0.1%
0 to 3, 10 to 13
0.1 to 1 s
0.1 s
0 to 20 s
0.1 s
0 to 500 A
0.01 A
0 to 3600 A
0.1 A
0 to 32767, 9999
0.5 to 30 kΩ, 9999
0.01 kΩ
(0 to 65535)
(0 to 65535)
0 to 400 Hz, 9999
1 Hz
0 to 300%
0 to 200%, 9999
0.1%
0 to 3
1,2
0 to 10 s, 9999
0.1 s
Parameter List
Initial value
Refer
to page
FM
CA
0 s
5-626
1
0
5-626
1
0
5-626
1
0
5-235
1
9999
5-235
60 Hz
50 Hz
5-341
0.1 s
5-248
0.1 s
5-248
0.1 s
5-248
0.1 s
5-248
9999
5-709
9999
5-655
5-673,
1
0
5-802
1
0
5-802
1
0
5-684
9999
5-684
1
0
5-626
1
9999
5-282
1
9999
5-282
9999
5-323
9999
5-543
1
0
5-543
1 s
5-237
0 s
5-237
Inverter rated
5-237
current
1
9999
5-581
9999
5-303
1
0
5-344
1
0
5-344
9999
5-692
1%
9999
5-692
9999
5-72
1
2
5-209
9999
5-259
5 - 17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents