Parameters
Description
Address
Upper 8 bits
RWrn+2E
Ninth monitor value
RWrn+2F
Tenth monitor value
RWrn+30
Output frequency
RWrn+31
RWrn+32
Output current
RWrn+33
Output voltage
RWrn+34
RWrn+35
Frequency setting value
RWrn+36
Running speed
RWrn+37
Motor torque
RWrn+38
Converter output voltage
RWrn+39
Regenerative brake duty
RWrn+3A
Electric thermal relay function load factor
RWrn+3B
Output current peak value
RWrn+3C
Converter output voltage peak value
RWrn+3D
Input power
RWrn+3E
Output power
RWrn+3F
Input terminal status
RWrn+40
Output terminal status
RWrn+41
RWrn+42
Motor excitation current
RWrn+43
Position pulse
RWrn+44
Cumulative energization time
RWrn+45
RWrn+46
Orientation status
RWrn+47
Actual operation time
RWrn+48
Motor load factor
RWrn+49
Cumulative power
RWrn+4A
Position command (lower digits)
RWrn+4B
Position command (upper digits)
RWrn+4C
Current position (lower digits)
RWrn+4D
Current position (upper digits)
RWrn+4E
Droop pulse (lower digits)
RWrn+4F
Droop pulse (upper digits)
RWrn+50
Torque command
RWrn+51
Torque current command
RWrn+52
Motor output
RWrn+53
Feedback pulse
RWrn+54
Tab. 5-345:
Remote registers (read) (2)
When Pr. 128 = "50, 51, 60, or 61", the register is valid.
The read value of an instruction code may differ when other writing of the settings and the several
instruction codes are executed simultane since instructions is processed in the order requested.
"n" indicates a value determined by the station number setting.
FR-A800
Refer to
Lower 8 bits
Reserved
Reserved
Load meter
Reserved
Reserved
Address
page
5-756
RWrn+55
5-756
RWrn+56
5-756
RWrn+57
RWrn+58
5-756
RWrn+59
5-756
RWrn+5A
RWrn+5B
5-756
RWrn+5C
5-756
RWrn+5D
5-756
RWrn+5E to
RWrn+61
5-756
RWrn+62
5-756
RWrn+63
5-756
RWrn+64
5-756
RWrn+65
5-756
RWrn+66
5-756
RWrn+67 to
5-756
RWrn+69
5-756
RWrn+6A
5-756
RWrn+6B
5-756
RWrn+6C
5-756
RWrn+6D
5-756
RWrn+6E
5-756
RWrn+6F
RWrn+70
5-756
RWrn+71
5-756
RWrn+72
5-756
RWrn+73
5-756
RWrn+74 to
RWrn+76
5-756
RWrn+77
5-756
RWrn+78
Cumulative pulse carrying-over times
5-756
RWrn+79
Cumulative pulse (control terminal option)
5-756
Cumulative pulse carrying-over times (control
5-756
RWrn+7A
5-756
RWrn+7B to
5-756
RWrn+7F
5-756
Tab. 5-345:
5-756
5-756
CC-Link IE Field Network (FR-A800-GF)
Description
Upper 8 bits
Lower 8 bits
Reserved
Trace status
Reserved
PLC function user monitor 1
PLC function user monitor 2
PLC function user monitor 3
Station number (RS-485 terminals)
Station number (PU)
Station number (CC-Link)
Reserved
Power saving effect
Cumulative saving power
PID set point
PID measured value
PID deviation
Reserved
Option input terminal status 1
Option input terminal status 2
Option output terminal status
Motor thermal load factor
Inverter thermal load factor
Reserved
PTC thermistor value
Reserved
PID measured value 2
Reserved
Cumulative pulse
terminal option)
Reserved
Remote registers (read) (3)
Refer to
page
5-756
5-756
5-756
5-756
5-756
5-756
5-756
5-756
5-756
5-756
5-756
5-756
5-756
5-756
5-756
5-756
5-756
5-756
5-756
5-756
5-756
5-756
5-756
5 - 751