Setting increment differs according to the combination of Pr. 37, Pr. 144, and Pr. 811. (Refer to page
5-341).
When Pr. 541 "Frequency command sign selection" = "1", the setting value has either + or -. When
the setting value is negative, the command is the inverse from the command.
Setting range: -327.68 Hz to 327.67 Hz (-327.68 to 327.67) 0.01 Hz increments. (Refer to page 5-673.)
When Pr.128 = "50, 51, 60, 61", they are valid.
If the data outside the range is set, the previous setting is retained. (Refer to page 5-543.)
Write data is in hexadecimal, and only two digits are valid. (The upper two digits are ignored.)
The value in RWw2 is used as the torque limit value during speed control or position control, and
as the torque command value during torque control. (Torque control cannot be performed with
a PM motor.) To use the value as the torque limit value, set Pr. 810 = "2".
FR-A800
CC-Link IE Field Network (FR-A800-GF)
5 - 755