Mitsubishi Electric FR-A820-00046 Instruction Manual page 242

Fr-a800 series
Hide thumbs Also See for FR-A820-00046:
Table of Contents

Advertisement

Parameter List
(D) Operation command and frequency command
Parameters that specify the inverter's command source,
and parameters that set the motor driving frequency and
torque.
Pr.
Pr.
Name
group
D000
79
Operation mode selection
Communication startup mode
D001
340
selection
Communication operation
D010
338
command source
Communication speed command
D011
339
source
NET mode operation command
D012
550
source selection
PU mode operation command
D013
551
source selection
Reverse rotation prevention
D020
78
selection
D030
811
Set resolution switchover
D100
291
Pulse train I/O selection
D101
384
Input pulse division scaling factor
D110
385
Frequency for zero input pulse
D111
386
Frequency for maximum input pulse
D200
15
Jog frequency
Multi-speed input compensation
D300
28
selection
Multi-speed setting (high speed)
D301
4
Simple
Simple
Simple
Multi-speed setting (middle speed)
D302
5
Simple
Simple
Simple
Multi-speed setting (low speed)
D303
6
Simple
Simple
Simple
D304 to
Multi-speed setting
24 to 27
D307
(4 speed to 7 speed)
D308 to
232 to
Multi-speed setting
D315
239
(8 speed to 15 speed)
D400
804
Torque command source selection
D401
805
Torque command value (RAM)
Torque command value (RAM,
D402
806
EEPROM)
D403
1114
Torque command reverse selection
Tab. 5-8:
Operation command and frequency
command
5 - 40
(H) Protective function parameter
Parameters to protect the motor and the inverter.
Pr.
group
Refer to
H000
page
5-271,
Simple
Simple
Simple
5-280
H001
5-280
H002
H003
5-282
H004
5-282
H005
5-282
H006
5-282
H010
5-291
H011
5-90,
5-341
H012
5-292,
5-358
H013
5-292
H014
5-292
H015
5-292
H016
5-296
H020
5-299
H021
5-299
H022
H030
5-299
H100
H101
5-299
H102
H103
5-299
H200
5-299
H201
5-90,
5-138
H300
5-90,
H301
5-138
H302
5-90,
H303
5-138
H400
5-138
H401
H402
H410
H411
H412
Tab. 5-9:
Pr.
Name
Electronic thermal O/L relay
9
Simple
Simple
Simple
First free thermal reduction
600
frequency 1
601
First free thermal reduction ratio 1
First free thermal reduction
602
frequency 2
603
First free thermal reduction ratio 2
First free thermal reduction
604
frequency 3
607
Motor permissible load level
51
Second electronic thermal O/L relay
Second free thermal reduction
692
frequency 1
693
Second free thermal reduction ratio 1
Second free thermal reduction
694
frequency 2
695
Second free thermal reduction ratio 2
Second free thermal reduction
696
frequency 3
608
Second motor permissible load level
561
PTC thermistor protection level
PTC thermistor protection detection
1016
time
Thermal protector input
876
875
Fault definition
244
Cooling fan operation selection
249
Earth (ground) fault detection at start
598
Undervoltage level
997
Fault initiation
Output phase loss protection
251
selection
Input phase loss protection selection
872
65
Retry selection
67
Number of retries at fault occurrence
68
Retry waiting time
69
Retry count display erase
1
Maximum frequency
2
Minimum frequency
18
High speed maximum frequency
807
Speed limit selection
Forward rotation speed limit/speed
808
limit
Reverse rotation speed limit/reverse-
809
side speed limit
Protective function parameter (1)
Parameters
Refer to
page
5-303,
5-72,
5-471
5-303
5-303
5-303
5-303
5-303
5-303
5-303,
5-72,
5-471
5-303
5-303
5-303
5-303
5-303
5-303
5-303
5-303
5-303
5-313
5-314
5-447
5-315
5-76
5-317
5-317
5-318
5-318
5-318
5-318
5-321
Simple
Simple
Simple
5-321
Simple
Simple
Simple
5-321
5-142
5-142
5-142