Calling A Subroutine Program In The Specified Program File And Turning The Output Off - Mitsubishi Electric MELSEC iQ-R Series Programming Manual

Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Calling a subroutine program in the specified program file and
turning the output off
EFCALL(P)
RnPCPU
RnPCPU
RnCPU RnENCPU
(Process)
(Redundant)
• [RnPCPU (redundant)] If these instructions are used in a program executed in both systems, there are restrictions on their operation in the standby system
when the redundant system is in backup mode. ( MELSEC iQ-R CPU Module User's Manual (Application))
These instructions perform non-execution processing of the subroutine program corresponding the specified pointer of the
specified program file name.
Ladder
(P)
(FILE)
(P)
(FILE)
FILE: File name
FBD/LD
EN
ENO
FILE
P
FILE: File name
■Execution condition
Instruction
EFCALL
EFCALLP
Setting data
■Descriptions, ranges, and data types
Operand
Description
(File name)
Program file name subject to non-execution processing
(P)
Start pointer number of subroutine program
*1
(s1) to (s5)
Device number to be passed to the subroutine program as
an argument
EN
Execution condition
ENO
Execution result
*1 Cannot be specified in FBD/LD.
RnSFCPU RnSFCPU
(Standard)
(Safety)
(s1)...(s5)
Execution condition
ST
Not supported
Range
Data type
Unicode string
Device name
-2147483648 to 2147483647
Bit/16-bit signed
binary/32-bit signed
binary
Bit
Bit
7 APPLICATION INSTRUCTIONS
7.4 Structure Creation Instructions
7
Data type (label)
ANYSTRING_DOUB
LE
POINTER
ANY
BOOL
BOOL
573

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents