Processing details
• These instructions convert the double-precision real number in the device specified by (s) to a single-precision real number,
and store the real number in the device specified by (d).
SM402
M0
• When an input value is set using the engineering tool, a rounding error may occur. Refer to the following for the precautions
on setting input values using the engineering tool.
Page 49 Precautions
Operation error
Error code
Description
(SD0)
The value input to (s) is -0, a subnormal number, NaN (not a number), or .
3402H
3403H
The data output from (d) exceeds the following range. (An overflow has occurred.)
|(d)|<2
7 APPLICATION INSTRUCTIONS
750
7.9 Real Number Instructions
EDMOVP E-123456.7
D0
(s)
(d)
DBL2FLT
D0
D100
128
(s)
b63
∙∙∙
b49
b48
∙∙∙
b32
D3, D2, D1, D0
C0FEH
240BH
(-123456.7)
(d)
b31
∙∙∙
b16
b15
∙∙∙
b0
4000H
0000H
D101, D100
b31
∙∙∙
b16
b15
∙∙∙
b0
C71FH
205AH
(-123456.7)