Mitsubishi Electric MELSEC iQ-R Series Programming Manual page 258

Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

■Applicable devices
Operand
Bit
X, Y, M, L,
SM, F, B, SB,
FX, FY
(s1)
(s2)
(d)
• In safety programs executed by the Safety CPU, only the following safety devices and constants can be used.
Operand
Bit
SA\X, SA\Y, SA\M, SA\SM, SA\B
(s1)
(s2)
(d)
Processing details
• These instructions multiply the 32-bit binary data in the device specified by (s1) by the 32-bit binary data in the device
specified by (s2), and store the operation result in the device specified by (d).
(s1)
(s1)+1
b31
b16 b15
b0
···
···
567890 (BIN)
×
• When (d) is a bit device, only the lower 32 bits of the operation result are stored. If the upper 32 bits of the operation result
are required, temporarily store the result in a word device, and transfer the data stored in (d)+2 and (d)+3 to the specified
bit devices.
Ex.
Operation result when (d) is a bit device
• K1Lower 4 bits (b0 to b3)
• K4Lower 16 bits (b0 to b15)
• K8Lower 32 bits (b0 to b31)
Operation error
There is no operation error.
6 BASIC INSTRUCTIONS
256
6.2 Arithmetic Operation Instructions
Word
J\
T, ST, C, D, W,
SD, SW, FD, R,
ZR, RD
(s2)
(s2)+1
(d)+3
b31
b16 b15
b63
b0
···
···
···
123456 (BIN)
U\G, J\,
Z
U3E\(H)G
Word
SA\T, SA\ST, SA\C, SA\D, SA\W, SA\SD
(d)+2
(d)
(d)+1
b48 b47
b31
b16 b15
b32
···
···
···
70109427840 (BIN)
Double word Indirect
specification
LT, LST,
LZ
LC
b0
Constant
Others
K, H E
$
Constant
K, H