Matrix Input Instruction; Matrix Input - Mitsubishi Electric MELSEC iQ-R Series Programming Manual

Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

7.18

Matrix Input Instruction

Matrix input

MTR
RnPCPU
RnCPU RnENCPU
(Process)
This instruction sequentially reads the input of 16 pointsn columns connected to the specified input number and after.
Ladder
(s)
FBD/LD
EN
ENO
s
d1
n
d2
■Execution condition
Instruction
MTR
Setting data
■Descriptions, ranges, and data types
Operand
Description
(s)
Start device of input
(d1)
Start device of output
(d2)
Start device for storing the matrix input data
(n)
Number of input columns
EN
Execution condition
ENO
Execution result
*1 Only labels assigned to device (X) can be used.
*2 Only labels assigned to device (Y) can be used.
*3 When specifying setting data by using a label, define an array to secure enough operation area and specify an element of the array
label.
■Applicable devices
Operand
Bit
X, Y, M, L,
SM, F, B, SB,
FX, FY
*1
(s)
*2
(d1)
(d2)
(n)
*1 Only X can be used.
*2 Only Y can be used.
7 APPLICATION INSTRUCTIONS
900
7.18 Matrix Input Instruction
RnPCPU
RnSFCPU RnSFCPU
(Redundant)
(Standard)
(Safety)
(d1)
(d2)
(n)
Execution condition
Word
J\
T, ST, C, D, W,
SD, SW, FD, R,
ZR, RD
ST
ENO:=MTR(EN,s,n,d1,d2);
Range
2 to 8
Double word Indirect
U\G, J\,
Z
LT, LST,
U3E\(H)G
LC
Data type
Data type (label)
Bit
ANY_BOOL
Bit
ANY_BOOL
Bit
ANY_BOOL
16-bit unsigned binary
ANY16
Bit
BOOL
Bit
BOOL
Constant
specification
LZ
K, H E
*1*3
*2*3
*3
Others
$