Calculating the exponentiation of single-precision real number

POW(P)
RnPCPU
RnPCPU
RnCPU RnENCPU
(Process)
(Redundant)
These instructions calculate the exponentiation of a single-precision real number.
Ladder
(s1)
(s2)
(d)
FBD/LD
EN
ENO
s1
d
s2
■Execution condition
Instruction
POW
POWP
Setting data
■Description, range, data type
Operand
Description
(s1)
Exponentiation recipient data or the start device containing
the exponentiation recipient data
(s2)
Exponentiation data or the start device containing the data
(d)
Start device for storing the operation result
EN
Execution condition
ENO
Execution result
■Applicable devices
Operand
Bit
X, Y, M, L,
J\
SM, F, B, SB,
FX, FY
(s1)
(s2)
(d)
RnSFCPU RnSFCPU
(Standard)
(Safety)
Execution condition
Word
T, ST, C, D, W,
U\G, J\,
SD, SW, FD, R,
U3E\(H)G
ZR, RD
ST
ENO:=POW(EN,s1,s2,d);
ENO:=POWP(EN,s1,s2,d);
Range
Data type
-126
128
|(s1)|<2
0, 2
Single-precision real
number
-126
128
|(s2)|<2
0, 2
Single-precision real
number
Single-precision real
number
Bit
Bit
Double word Indirect
Z
LT, LST,
LZ
LC
7 APPLICATION INSTRUCTIONS
Data type (label)
ANYREAL_32
ANYREAL_32
ANYREAL_32
BOOL
BOOL
Constant
Others
specification
K, H E
$
7.9 Real Number Instructions