Mitsubishi Electric MELSEC iQ-R Series Programming Manual page 971

Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

■Applicable devices
Operand
Bit
X, Y, M, L,
J\
SM, F, B, SB,
FX, FY
(s1)
(s2)
(s3)
(s4)
(d1)
(d2)
(d3)
■Search target table name
Operand: (s2)
Device
Item
+0 to +
Table name
■Search target field name
Operand: (s3)
Device
Item
+0
Number of fields
+1 to +
Field name
*1 "0" to "16" for a programmable controller CPU with firmware version earlier than "28"
The following figure shows the format of (s3).
b15
(s3)
(s3)+1
1
(s3)+32
n
(s3)+32*n
Word
T, ST, C, D, W,
U\G, J\,
SD, SW, FD, R,
U3E\(H)G
ZR, RD
Description
Specify the search target table name with up to 32 characters.
Description
Specify the number of fields to be searched.
If 0 is specified, all fields of the table are subject to output.
Specify each search target field name with 32 characters. The last address in (s3)
varies according to the number of fields.
=33n
Specify field names, each fixed to 32 characters, by the number of fields with
Unicode character strings. For the name less than 32 characters, the character string
should be right-justified and filled with 0000H to become a 32-character string.
This setting of this item is not necessary when "0" is specified in (s3)+0. (Ignored if
specified.)
b0
Set the number of fields, 'n'.
A field name set in the 1st field
A field name set in the 'n'th field
Double word Indirect
specification
Z
LT, LST,
LZ
LC
Data for 'n' fields (If zero is
set to (s3), setting for these
data is not required.)
7 APPLICATION INSTRUCTIONS
7.21 Database Access Instructions
Constant
Others
K, H E
$
Setting range
Set by
User
Setting range
Set by
*1
0 to 128
User
User
969
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents