Mitsubishi Electric GOT2000 Series Connection Manual page 494

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

■2. TOSHIBA PLC (TOSHIBA PROSEC T/V Series)
External input (X)
External output (Y)
Internal relay (R)
Special relay (S)
Link register relay (Z)
Bit device
Link relay (L)
Timer (Contact) (T)
Counter (Contact) (C)
The bit specification of the word device
(except external input, external output, internal relay, special relay
link relay, timer and counter)
External input (XW)
External output (YW)
Internal relay (RW)
Special relay (SW)
Link relay (LW)
Word device
Timer (Current value) (T)
Counter (Current value) (C)
Data register (D)
*3*6*8
Link register (W)
File register (F)
PROSEC T Series
*1
*2
*3
*4
PROSEC V Series
*5
*6
*7
*8
12 - 20
12.4 Device Range that Can Be Set
Device name
*7
*7
*1
*1
*6*8
*8
*1
*1
*4
The writing of the timer (contact)/(current value) and counter (contact)/(current value) are executed after being read by the GOT.
Therefore, do not edit it in the sequence program during this period.
As bit specification of a word device is performed after the GOT reads the value, do not change the value in the sequence
program during this period.
When the mode switch on the CPU module is set to "P-RUN", writing to D0000 through D4095 is disabled.
Extension file register is not supported.
As bit specification of a word device is performed after the GOT reads the value, do not change the value in the sequence
program during this period.
RW0000 and D0000 indicate the data register in the same region although they are shown in different notations.
For bit data, the conversion from the address notation for the TOSHIBA PLC to that for the GOT is shown as follows.
Address notation for TOSHIBA PLC ÷ 16=Word address (Quotient)...Bit address (Remainder)
Address notation
for TOSHIBA PLC
S8191
R65535
For word data, the conversion from the address notation for the TOSHIBA PLC to that for the GOT is shown as follows.
Communication format
16bit data
32bit data
*2*5*7
Address notation
for GOT
S511F
(Decimal) (Hexadecimal)
R4095F
(Decimal) (Hexadecimal)
(Integer)
(Calculate the device No. in 32-bit unit)
(Real number)
(Calculate the device No. in 32-bit unit)
Setting range
X0000 to X511F
Y0000 to Y511F
R0000 to R4095F
S0000 to S511F
Z0000 to Z999F
L0000 to L255F
T0 to T999
C0 to C511
Setting range of each word device
XW0 to XW511
YW0 to YW511
RW0 to RW4095
SW0 to SW511
LW0 to LW255
T0 to T999
C0 to C511
D0 to D8191
W0 to W2047
F0 to F32767
Conversion
8191÷16= 511...15
65535÷16= 4095...15
Address notation
for TOSHIBA PLC
DW10
DD10
DF10
Device No.
representation
Hexadecimal
Decimal
-
Decimal
Address notation
for GOT
D10
D20
D20