14.7 Precautions

■1. Station number setting in the servo system
Configure the servo system so that there is a servo amplifier with a station number set with a host address.
For details of host address setting, refer to the following manual.
14.4.2 Communication detail settings
■2. Monitor speed
When monitoring multiple station devices placed on the same GOT screen, the monitor speed is slow. Even when
monitoring a single station, the monitor speed is slow if the device points is large.
■3. Mixing of MINAS A4 series and MINAS A5 series
MINAS A4 series and MINAS A5 series cannot be mixed. The multiple MINAS A4 series can be used together.
14 - 19