Download Print this page
Mitsubishi Electric GOT SIMPLE GS2107-WTBD Installation Manual

Mitsubishi Electric GOT SIMPLE GS2107-WTBD Installation Manual

Operator terminals, human-machine interfaces
Hide thumbs Also See for GOT SIMPLE GS2107-WTBD:

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

Quick Links

GOT2000 Series Operator
Terminals
Human-Machine Interfaces
Installation Manual for GOT SIMPLE
GS2110-WTBD and GS2107-WTBD
Art. no.: 288866 ENG, Version A, 06022015
Safety Information
For qualified staff only
This manual is only intended for use by properly trained and qualified electri-
cal technicians who are fully acquainted with automation technology safety
standards. All work with the hardware described, including system design,
installation, setup, maintenance, service and testing, may only be performed
by trained electrical technicians with approved qualifications who are fully
acquainted with the applicable automation technology safety standards and
regulations.
Proper use of equipment
The GOT2000 series operator terminals GOT SIMPLE (GS2110, GS2107) are only
intended for the specific applications explicitly described in this manual or
other manuals. Please take care to observe all the installation and operating
parameters specified in the manual. All products are designed, manufactured,
tested and documented in agreement with the safety regulations. Any modi-
fication of the hardware or software or disregarding of the safety warnings
given in this manual or printed on the product can cause injury to persons or
damage to equipment or other property. Only accessories and peripherals
specifically approved by MITSUBISHI ELECTRIC may be used. Any other use or
application of the products is deemed to be improper.
Relevant safety regulations
All safety and accident prevention regulations relevant to your specific appli-
cation must be observed in the system design, installation, setup, mainte-
nance, servicing and testing of these products.
In this manual special warnings that are important for the proper and safe use
of the products are clearly identified as follows:
P
DANGER:
Personnel health and injury warnings.
Failure to observe the precautions described here can result
in serious health and injury hazards.
E
CAUTION:
Equipment and property damage warnings.
Failure to observe the precautions described here can result
in serious damage to the equipment or other property.
Further Information
More information about the operator terminals of the GOT2000 series and the
configuration tool MELSOFT GT Works3 is available free of charge through the
internet (https://eu3a.mitsubishielectric.com).
If you have any questions concerning the installation, configuration or opera-
tion of the equipment described in this manual, please contact your relevant
sales office or department.
Dimensions
GS2110
272
All dimensions are in „mm".
GS2107
206
All dimensions are in „mm".
Panel Cut Out
A space of at least 10 mm at the
upper and lower side of the
10 or more
GOT is required to allow for the
attachment of mounting fix-
tures.
B
Cut Out [mm]
GOT
A
GS2110
258
10 or more
GS2107
191
A
Unit: mm
Distances to other devices
When mounting the GOT, please maintain the following clearances from other
devices.
B
Other device
C
D
E
GOT
A
Panel*
* Panel thickness: 1.6 to 4.0 mm
Minimum clearances [mm]
Distances to other
devices
A
B
C
D
GS2110, GS2107
50
80
50
50
Installation and Wiring
56
P
DANGER
6
● Switch OFF the power supply of the operator terminal before starting
the installation work or wiring and before mounting or removing the
option function board.
● When the communication between the operation terminal and the
PLC fails it is impossible to operate keys or devices via the operation
terminal. Therefore emergency stops and other safety functions must
not be controlled via the PLC.
E
CAUTION
● Do not disassemble or modify the unit. Doing so can cause a failure,
50
malfunction, injury or fire.
6
● Use the GOT in the environment that satisfies the general specifica-
tions described in this manual. Don't mount the operation terminal in
an enviroment that contains high explosive risks, strong magnetic
fields, direct sunlight or large, sudden temperature changes.
● Never allow fluids, metal filings or wiring debris to enter any openings
in the operator terminal. This may cause short circuits and fire.
Mounting
A GOT is designed to be installed into the door of a control cabinet or into a
control panel.
When the temperature inside the control cabinet or
control panel is 40 to 55 °C the mounting angle
105°
should be in the range 60° to 105° degrees.
GOT
60°
Prepare a hole in the panel with the dimensions shown on the left.
Insert the GOT from the front of the
B
panel or the control cabinet into
+2
+2
200
the cut out.
–0
–0
+2
+2
137
–0
–0
GOT
Place the mounting fittings (sup-
plied) into the provided openings
of the GOT and tighten the screws
until the GOT is fixed. Please use all
four supplied mounting fittings
and tighten the mounting screws
with a torque of 0.36 to 0.48 Nm.
E
After mounting, remove the protection film from the operator terminal display.
100
Power Supply Wiring
E
CAUTION
● Do not lay signal cables close to the main circuit, high-voltage power
lines, or load lines. Otherwise effects of noise or surge induction are
likely to take place. Keep a safe distance of more than 100 mm from
the above when wiring.
● When connecting the power supply please confirm the rated voltage
and the polarity. Not doing so can cause a fire or failure.
Connect the power supply to the power terminals on the back panel of the GOT.
Grounding
24 V DC
Use the thickest cable possible (max. 2 mm
start twisting them close to the connection terminals. Tighten the terminal
screws securely with a torque of 0.5 to 0.6 Nm.
Use commercially available ferrules with plastic sleeve for connection of the
power supply (see figure below).
Insulation sleeve
2.8–4.2 mm
8–12 mm
14–18 mm
Grounding
Ground the GOT using the ground terminal at the lower left corner of the oper-
ator terminal (Refer to the figure at the top of this column).
● The grounding resistance should be 100
● The grounding point should be close to the GOT. Keep the grounding wires
Cut out
as short as possible.
● The ground wire size should be at least 2 mm
● Independent grounding should be performed for best results. When inde-
Magnified illustration
pendent grounding is not performed, perform "shared grounding" of the
following figure.
Other
GOT
GOT
equipment
Mounting
Independent grounding
Shared grounding
fitting
Best condition
Good condition
Mounting
screw
Connection to the Control System
An operator panel of the GOT2000 series can be connected not only to PLCs
from Mitsubishi Electric but also to inverters, servo amplifiers, CNC as well and
to PLCs from third party manufacturers and many other devices. For further
information please refer to the Connection Manual for the GOT2000 series.
Mitsubishi Electric Europe B.V. /// FA - European Business Group ///
Germany /// Tel.: +49(0)2102-4860 /// Fax: +49(0)2102-4861120 ///
https://eu3a.mitsubishielectric.com
GS2110-WTBD, GS2107-WTBD
2
) to minimize the voltage drop and
Terminal contact section
or less.
2
.
Other
Other
GOT
equipment
equipment
Common grounding
Not allowed

Advertisement

loading

Summary of Contents for Mitsubishi Electric GOT SIMPLE GS2107-WTBD

  • Page 1 An operator panel of the GOT2000 series can be connected not only to PLCs If you have any questions concerning the installation, configuration or opera- from Mitsubishi Electric but also to inverters, servo amplifiers, CNC as well and tion of the equipment described in this manual, please contact your relevant to PLCs from third party manufacturers and many other devices.
  • Page 2 Ihrer Vertriebspartner zu kontaktieren. Steuerungen sowie an SPS von Fremdherstellern und vielen anderen Geräten. Weitere Informationen enthält die Bedienungsanleitung zur GOT2000-Serie (Anschluss). Mitsubishi Electric Europe B.V. /// FA - European Business Group /// Germany /// Tel.: +49(0)2102-4860 /// Fax: +49(0)2102-4861120 /// https://de3a.mitsubishielectric.com...
  • Page 3 à des appareils d’autres fabri- cants. Pour en savoir plus, voir le Manuel de connexion de la Série GOT2000. Mitsubishi Electric Europe B.V. /// FA - European Business Group /// Germany /// Tel.: +49(0)2102-4860 /// Fax: +49(0)2102-4861120 ///...
  • Page 4: Specifications

    GS2110-WTBD/GS2107-WTBD GS2110-WTBD/GS2107-WTBD GS2110-WTBD GS2107-WTBD General Specifications Power Supply Specifications Specifications Specifications Umgebungsbedingungen Spannungsversorgung Technische Daten Technische Daten Conditions générales de service Alimentation en courant Caractéristiques techniques Caractéristiques techniques Item / Merkmal / Description / Beschreibung / Item / Merkmal/ Description / Beschreibung / Item / Merkmal / Description / Beschreibung / Item / Merkmal /...
  • Page 5 GOT2000 si possono utilizzare solo unità aggiuntive o di espansione con- GS2110 co o del pulpito attraverso l’apertu- sigliate da MITSUBISHI ELECTRIC. Ogni altro utilizzo o applicazione che vada –0 –0 oltre quanto illustrato è da considerarsi non conforme.
  • Page 6 Un terminal de operador de la serie GOT2000 puede conectarse no sólo a PLCs Otras informaciones de Mitsubishi Electric, sino también a inverters, servoamplificadores, CNCs y a PLCs de terceros y a muchos otros dispositivos. Para obtener información adi- Puede obtenerse gratuitamente vía Internet (https://eu3a.mitsubishielectric.com) cional, consulte el Manual de Conexión de la serie GOT2000.
  • Page 7 Если возникнут вопросы по установке, конфигурированию и эксплуа- тации панелей оператора, обратитесь в ваше региональное торговое представительство или к вашему региональному торговому партнеру. Mitsubishi Electric Europe B.V. /// FA - European Business Group /// Germany /// Tel.: +49(0)2102-4860 /// Fax: +49(0)2102-4861120 /// https://eu3a.mitsubishielectric.com...
  • Page 8 GS2110-WTBD/GS2107-WTBD GS2110-WTBD/GS2107-WTBD GS2110-WTBD GS2107-WTBD Condizioni di funzionamento generali Alimentazione Specifiche tecniche Specifiche tecniche Condiciones ambientales Especificaciones de alimentación eléctrica Datos técnicos Datos técnicos Окружающая среда Электропитание Технические характеристики Технические характеристики Caratteristica / Característica / Descrizione / Descripción / Caratteristica / Característica / Descrizione / Descripción / Caratteristica / Característica / Descrizione / Descripción /...
  • Page 9 Jeśli masz jakiekolwiek pytania związane z instalacją, konfiguracją lub obsługą sprzętu opisanego w tej instrukcji, prosimy o kontakt z właściwym biurem han- dlowym lub oddziałem. Mitsubishi Electric Europe B.V. /// FA - European Business Group /// Germany /// Tel.: +49(0)2102-4860 /// Fax: +49(0)2102-4861120 /// https://eu3a.mitsubishielectric.com...
  • Page 10 MELSOFT GT Works3 konfigurációs szoftverre vonatkozó adatok ingyenesen védőfóliát. elérhetők az interneten keresztül (https://eu3a.mitsubishielectric.com). A GOT2000 sorozathoz tartozó operátor panelek nem csupán a Mitsubishi Electric által gyártott PLC készülékekhez csatlakoztathatók, hanem más gyártók által Ha bármilyen kérdése van az útmutatóban leírt berendezés beszerelésével készített frekvenciaváltókhoz, szervoerősítőkhöz, CNC gépekhez és PLC készü-...
  • Page 11 GOT2000 (Připojení). GOT2000 se obracejte na příslušné prodejní místo nebo na některého z vašich distributorů. Mitsubishi Electric Europe B.V. /// FA - European Business Group /// Germany /// Tel.: +49(0)2102-4860 /// Fax: +49(0)2102-4861120 /// https://eu3a.mitsubishielectric.com...
  • Page 12 Daha fazla bilgi için, lütfen GOT2000 serisinin Haberleşme Kılavuzuna bakın. Mitsubishi Electric Europe B.V. /// FA - European Business Group /// Germany /// Tel.: +49(0)2102-4860 /// Fax: +49(0)2102-4861120 /// https://eu3a.mitsubishielectric.com...
  • Page 13 GS2110-WTBD/GS2107-WTBD GS2110-WTBD/GS2107-WTBD GS2110-WTBD GS2107-WTBD Ogólne dane techniczne Dane techniczne zasilania Dane techniczne Dane techniczne Műszaki jellemzők A tápegység adatai Specifikációk Specifikációk Provozní podmínky Napájecí napětí Technické údaje Technické údaje Genel Özellikler Besleme Özellikleri Özellikler Özellikler Pozycja / Tétel / Parametr / Öğe Opis / Leírás / Popis / Açıklama Pozycja / Tétel / Parametr / Öğe Opis / Leírás / Popis / Açıklama...

This manual is also suitable for:

Got simple gs2110-wtbdGot2000 series