Mitsubishi Electric GOT2000 Series Connection Manual page 292

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

■2. Indirect specification
When setting the device, indirectly specify the station number of the temperature controller of which data is to be
changed using the 16-bit GOT internal data register (GD10 to GD25).
When specifying the station No. from 100 to 115 on GT Designer3, the value of GD10 to GD25 compatible to the
station No. specification will be the station No. of the temperature controller.
Specification station NO.
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
■3. All station specification
Target station differs depending on write-in operation or read-out operation.
• For write-in operation, all station will be a target.
• For read-out operation, only one station will be a target.
5 - 30
5.5 Temperature Controller Side Setting
Compatible device
GD10
GD11
GD12
GD13
GD14
GD15
GD16
0 to 99: For E5AN, E5EN, E5CN or E5GN
GD17
0 to 15: For E5ZN
GD18
For the setting other than the above, error (dedicated device is out of range) will occur.
GD19
GD20
GD21
GD22
GD23
GD24
GD25
Setting range