Bosch Praesideo 3.5 Installation And User Instructions Manual page 473

Digital public address and emergency sound system
Table of Contents

Advertisement

Praesideo 3.5 | Installation and User Instructions | 11 | Optional Software
table 59. 1 : Item list of PCCstImages
33A/C
Zone status: occupied by other emergency call (unselected, selected for emergency call)
33F/H
Zone group status: occupied by other emergency call (unselected, selected for emergency call)
34A-C
Zone status: occupied by other emergency call, no control possible (unselected, selected for
business call, selected for emergency call)
34F-H
Zone group status: occupied by other emergency call, no control possible (unselected, selected
for business call, selected for emergency call)
35A-C
Zone status: free, no control possible (unselected, selected for business call, selected for
emergency call)
35F-H
Zone group status: free, no control possible (unselected, selected for business call, selected for
emergency call)
36B/C
Zone status: running own call (business, emergency)
36G/H
Zone group status: running own call (business, emergency)
37A/B
Zone status: BGM (unselected, selected)
37F/G
Zone group status: BGM (unselected, selected)
38A/B
Zone status: local BGM (unselected, selected)
38F/G
Zone group status: local BGM (unselected, selected)
39A
Zone status: BGM, no control possible
39F
Zone group status: BGM, no control possible
40A
Zone status: local BGM, no control possible
40F
Zone group status: local BGM, no control possible
41B
Zone status: occupied by selected BGM channel
41G
Zone group status: occupied by selected BGM channel
42A
Zone status: no status available due to communication error
42F
Zone group status: no status available due to communication error
43A
Zone status: icon overlay for zone fault
43F
Zone group status: icon overlay for zone fault
44F-H
Zone group status: partially occupied by other call, some control possible (unselected, selected
for business call, selected for emergency call)
45F-H
Zone group status: partially occupied by other call, no control possible (unselected, selected for
business call, selected for emergency call)
46G/H
Zone group status: running own partial call (business, emergency)
The file PCCstImageDef.xml, see figure 59.27, which is
located in the folders
C:\Program Files\Bosch\Praesideo
Vx.yy.zzzz\Programs\PCCstConfgurationClient\ and
C:\Program Files\Bosch\Praesideo
Vx.yy.zzzz\Programs\PCCstClient\ contains information
about the actual position and size of the buttons, icons
and indicators in the PCCstImages.png file. Making
changes to this xml-file allows for changing the size or
position of individual items of the PCCstImages.png file
because it is used as a reference for the coordinates of
the actual items in the png-file. The files
PCCstImageDef.xml and PCCstImages.png in the same path
belong to each other.
Bosch Security Systems | 2011-02
figure 59.27: PCCstImageDef.xml
en | 473