47.2.3 Single shot behaviors
47.2.3. 1 Single shot
If the behavior is single shot, the action is started when
the external contact closes. The action can be stopped
with a single shot with immediate abort (see section
47.2.3.2) or single shot with phase completion (see
section 47.2.3.3).
make
break
action
start/stop
start
figure 47.5: Single shot
Usually, the single shot behavior is used for triggering
events (for example, to cancel a selection) and actions
with a significant duration (for example, a call).
47.2.3.2 Single shot with immediate abort
If the behavior is single shot with immediate abort, the
action is stopped when the external contact closes. This
type of behavior is used for stopping actions that were
started with a single shot action (see section 47.2.3.1)
47.2.3.3 Single shot with phase completion
If the behavior is single shot with phase completion, the
action is stopped when the external contact closes. This
type of behavior is used for stopping actions that were
started with a single shot action (see section 47.2.3.1)
47.2.4 Toggle behaviors
47.2.4. 1 Toggle
If the behavior is toggle, the action coupled to the
control input or key is started when the external contact
closes and stopped when the external contact closes
again (see figure 47.6).
make
break
action
figure 47.6: Toggle
Bosch Security Systems | 2011-02
call
47.2.4.2 Toggle with immediate abort
If the behavior is toggle with immediate abort, the
action coupled to the control input or key is started
when the external contact closes and immediately
aborted when the external contact closes again. For an
example, see figure 47.7.
make
break
action
start/stop
start
call
figure 47.7: Toggle with immediate abort
47.2.4.3 Toggle with phase completion and abort on
repress
If the behavior is toggle with phase completion and
abort on repress, the action coupled to the control input
or key is started when the external contact closes. For an
example, see figure 47.8. When the external contact
closes again, the action is stopped after the completion
of the current phase.
make
break
action
start/stop
start
call
figure 47.8: Toggle with phase completion and abort on
repress (1)
When the external is closed a third time while the action
is still running, the action is immediately aborted. For an
example, see figure 47.9.
make
break
action
start/stop
start
call
figure 47.9: Toggle with phase completion and abort on
repress (2)
en | 385
abort
stop
stop
abort