figure 59.5: Configure network controllers
figure 59.6: Add new, Delete and Copy to new icons
Use the Add new icon to add a network controller, see
figure 59.6. Fill in the unique name and IP-address or
host name of the network controller and a valid user
name and password for that network controller. Use the
Delete icon to delete the network controller from the list
of network controllers. The Copy to new icon creates a
new copy of the current network controller for
subsequent editing.
59.5.4.2 Get Configuration
This item retrieves the relevant configuration data from
the configured network controllers, such as the names of
zones, messages, tones, inputs, etc. The progress of the
data retrieval is shown. When the transfer is completed
you can accept or reject the data. This data is needed for
further configuration. A warning is shown if the tone set
and message set are not the same on all network
controllers because this will limit the choice of tones and
messages for the connected clients, see section 59.5.4.4.
This option is not available when working offline.
Bosch Security Systems | 2011-02
figure 59.7: Get configuration
59.5.4.3 Configure Interconnections...
This item configures the interconnections between the
different network controllers.
figure 59.8: Configure interconnections
These interconnections are the actual hardware
connections for audio transfer between the systems, and
are needed to transfer a call from one Praesideo
subsystem to another. A connection is not necessarily
between network controllers but uses a configured zone
in one system as a source and an audio input in another
system as a destination. Zones can be line outputs on
e.g. a network controller or audio expander and inputs
can be line inputs on such units interconnected via XLR
cables, but it is also possible to use inputs and outputs of
CobraNet interfaces, interconnected via Ethernet. It is
not possible (and useful) to make interconnections
between inputs and outputs within the same subsystem.
Use the Add new and Delete icons to create new