General Run Problems
Problem
Battery does not charge.
Engine kills during operation.
Workman 1100/1110/2100/2110
Possible Causes
Wiring to the charging circuit (see Wiring Schematics)
components is loose, corroded, or damaged.
Voltage regulator and/or starter/generator is faulty.
Battery is dead.
Wiring to the run circuit (see Wiring Schematics)
components became broken or disconnected.
RPM shutdown module is faulty (Workman 2100 and
2110).
Engine or fuel system is malfunctioning (see Engine
Chapter).
Page 6 – 5