Cisco Catalyst 2950 Hardware Installation Manual page 135

Desktop switch
Hide thumbs Also See for Catalyst 2950:
Table of Contents

Advertisement

Chapter 4
Troubleshooting
Table 4-1
Common Problems and Solutions (continued)
Symptom
System LED is amber.
Switch placed in
error-disabled state after
5
CWDM
GBIC or SFP
module is inserted.
78-11157-05
Possible Cause
Internal fan fault detected.
Nonfatal or fatal POST error
detected.
Bad or non-Cisco-approved CWDM
GBIC module or SFP module.
Catalyst 2950 Desktop Switch Hardware Installation Guide
Diagnosing Problems
Resolution
Check if the fan has failed
by using the show env fan
privileged EXEC command.
If the fan has failed, call
Cisco Systems.
Use the show post
privileged EXEC command
to see which POST test
failed.
Remove the CWDM GBIC or
SFP module from the switch,
and replace it with a
Cisco-approved module. Use the
errdisable recovery cause
gbic-invalid global
configuration command to
verify port status, and enter a
time interval to recover from the
error-disabled state.
Refer to the switch software
configuration guide for
information about the
errdisable recovery command.
4-5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents