Messages and Diagnostic Codes

Table 19 DE Messages

Write NVM Failed
Unknown Device
Invalid Range
Invalid Request
NACK
Illegal Operation
Transmitter in Local Mode
Transmitter is Busy
Invalid operation on Write Protected
Field
Undefined Gross Status Byte from the
Transmitter
Gross Status Reserved Bit Set
Data Inaccessible
Bad character in Scratchpad
Invalid Float value
Value Out of Range
Transmitter is in DE Mode. D/A Trim is
allowed only in Analog Mode.
The transmitter is in Output Mode. Are
you sure you want to terminate the
connection?
The changes you have made are about
to be sent to the transmitter. Continue?
Please make sure you are connected to
a DE device. Sending DE commands to
a non-DE device could potentially cause
a process upset.
Leaving the Main Menu will require an
upload in order to return. Are you sure
you want to do this?
Put loop in Manual ... Trips secured?
Conformity must be square root to
select this unit.
Page 68
DE MESSAGES
Write to transmitter Non-Volatile Memory failed.
MC Toolkit does not support this transmitter.
User-entered value is too high or too low.
This transmitter does not support the command requested.
MC Toolkit sensed Non-Acknowledgement of message to the
Transmitter.
Typically caused by an invalid parameter or an attempt to perform an
operation in a mode not allowed by the transmitter.
Transmitter in Factory Mode
Transmitter was communicating when MC Toolkit sent message to
transmitter.
Attempt to write to a protected field.
The transmitter has reported a status indication not understood by MC
Toolkit.
The transmitter has reported a status indication not understood by MC
Toolkit.
Unable to access the parameter value.
The scratchpad contains an invalid data byte.
Value is not a valid floating point value.
User-entered number is too high or too low.
DE mode is digital only (no digital-to-analog conversion).
User tried to Exit MC Toolkit application while the DE Transmitter is still
in Output Mode.
Values entered into this display will be written into transmitter memory.
DE communications (~ 4-20 mA amplitude) could cause erroneous
transmission in non-DE protocols.
A new Upload will require approximately 60-second wait.
Changing values of transmitter parameters can cause process upset.
Units for Flow indications are available only when Square Root
conformity is selected.