*1. RD77MS2 does not have the connectors 2A20 to 2A1 and 2B20 to 2B1.
*2. Set the signal input form in "[Pr.24] Manual pulse generator/Incremental synchronous encoder input
selection".
*3. With the manual pulse generator/incremental synchronous encoder of voltage-output/open-collector type
Connect the A-phase/PULSE signal to HA, and the B-phase/SIGN signal to HB.
*4. With the manual pulse generator/incremental synchronous encoder of differential-output type
Connect the A-phase/PULSE signal to HAH, and the A-phase/PULSE inverse signal to HAL.
Connect the B-phase/SIGN signal to HBH, and the B-phase/SIGN inverse signal to HBL.
*5. Do not connect to any terminals explained as "No connect".
*6. Set the external command signal [DI, FLS, RLS, DOG, STOP] in "[Pr.116] FLS signal selection", "[Pr.117]
RLS signal selection", "[Pr.118] DOG signal selection", "[Pr.119] STOP signal selection" and "[Pr.95]
External command signal selection".
*7. Do not connect wires other than the signal wires of the manual pulse generator to 1A20 and 1A19.
*8. Do not use 1A(B)15 and 1A(B)14 for other than the power supply of manual pulse generator.
3.5.1

Input/output interface signals

(1) Internal circuit of RD77MS interface
The schematic view of the internal circuit of the external device connection interface of
RD77MS is shown below.
(a) Interface between external input signals/forced stop input signals
Input or
Signal name
Output
External input
signals
*1
(upper/lower
limit signal
External input
signal
*1
(proximity dog
stop, external
Input
command/
switching signal)
Common
Forced stop
input
*1. When using external input signal of servo amplifier, set "1" with "[Pr.116] FLS signal selection", "[Pr.117]
RLS signal selection", and "[Pr.118] DOG signal selection".
*2. Refer each servo amplifier instruction manual for wiring of the input/output signals of servo amplifier.
*3. "_ _" indicates "1A", "1B", 2A ", or "2B".
*4. As for the 24 V DC sign, both "+" and "-" are possible.
Pin No.
SIN
(FLS,
RLS)
*2
)
_ _1 to 5
SIN
*2
,
(DOG,
STOP,
DI)
_ _6
COM
_ _7
EMI
1A8
EMI.
1B8
COM
Wiring example
SIN (FLS, RLS)
*3
SIN (DOG, STOP, DI )
*4
24 V DC
COM
*3
EMI
*3
EMI.COM
3-20
Description
Internal circuit
Upper limit signal
Lower limit signal
Proximity dog
signal
Stop signal
External command
signals
Switching signal
External forced
stop input