Home Position Return - Mitsubishi Electric FATEC MELSEC iQ-R Training Manual

Table of Contents

Advertisement

6.8.3

Home position return

Perform operation on the JOG•home position return operation screen in the same manner
as in the case of the JOG operation.
(1) Touch Home position return
(2) After the operation is stopped, check Axis 1 home position return U0¥G2417.4, Axis 2 home position
return U0¥G2517.4 and Axis 3 home position return U0¥G2617.4. If the axes have returned correctly to
their home positions, the lamps of the axes are on.
(2)
, and home position return will be started.
M1020
(3) When the home position return has been normally
(4) After the completion of home position return, touch
Screen
switching
The menu is
displayed.
6-47
(1)
completed, check that the positioning addresses
are the values shown left (home position
addresses).
JOG•home position
to turn off M6800.
M6800
Touch
to display the screen switching menu.
Menu