Address Indirect Specification Positioning - Mitsubishi Electric FATEC MELSEC iQ-R Training Manual

Table of Contents

Advertisement

6.8.6

Address indirect specification positioning

Perform operation on the positioning operation screen in the same manner as in the case of
the standby point positioning and point selection positioning.
(3) Touch
(2).
M12 is on during address indirect specification positioning operation.
The address indirect specification positioning trajectory is as shown below.
Axis 2
-5 mm
-5 mm
(Current position) (Specified position)
Home
position
Indirect specification
, and the Axis 1 will be positioned in the positioning address input in
M2
Axis 1
Go to next page
(1) Touch the set value of D2000 setting, and the
numeric input window will appear.
(2) Input the positioning address arbitrarily.
The input range is from 0 to 140 (mm).
Touch
, and the input value will be
ENTER
reflected.
(Example) When the input value is 70: (Axis 1) =
(70)
[Operation example]
Address indirect specification positioning from (20, -5) to (70, -5)
(4) Upon completion of point selection positioning,
check that the positioning address of X-axis in the
feed current value field is the value set in (2).
6-51