Appendix 7.2 System Configuration - Mitsubishi Electric FATEC MELSEC iQ-R Training Manual

Table of Contents

Advertisement

Appendix 7.2 System Configuration

(1) System Configuration
FX5U/FX5UC
CPU module
Ethernet
cable
Peripheral
device
(Computer)
Manual pulse generator/Incremental
synchronous encoder
1 unit
<External command signal via CPU>
・Upper stroke limit
・Lower stroke limit
・Proximity dog signal
・Stop signal
External command signal (4 points)
Forced stop input (24 V DC)
(2) Compatible modules
Model name
FX5U CPU module
FX5UC CPU module
*1. To connect with FX5UC CPU module, FX5-CNV-IF or FX5-C1PS-5V is required.
Simple motion
module
SSCNET III
cable
External input
signal cable
Servo
motor
• FX5-40SSC-S: Ver. 1.000 or later
• FX5-80SSC-S: Ver. 1.014 or later
• FX5-40SSC-S: Ver. 1.000 or later
*1
• FX5-80SSC-S: Ver. 1.014 or later
App-67
External input signals of servo amplifier
・Upper stroke limit
・Lower stroke limit
・Proximity dog signal
Servo
motor
Compatible versions
Servo
motor

Advertisement