MDS 05-4670A01, Rev. E

Major Alarms vs. Minor Alarms

Major Alarms (1-16)—report serious conditions that generally indicate
a hardware failure, or other abnormal condition that will prevent (or
seriously hamper) further operation of the transceiver. Major alarms
generally indicate the need for factory repair. Contact your Technical
Service representative for further assistance.
Minor Alarms (17-32)—report conditions that, under most circum-
stances, will not prevent transceiver operation. This includes out-of-tol-
erance conditions, baud rate mismatches, etc. The cause of these alarms
should be investigated and corrected to prevent system failure.

Event Code Definitions

Table 14 contains a listing of event codes that can be reported by the
transceiver. The codes shown are a subset of a larger pool of codes used
for various GE MDS products. For this reason, the table does not show
a sequential listing of all code numbers. Only the codes applicable to this
product are shown, and this list is subject to change with product revi-
sion.
Event
Event
Code
Class
02
Major
03
Major
04
Major
08
Major
09
Major
12
Major
13
Major
14
Major
16
Minor
26
Minor
29
Minor
31
Minor
37
Minor
38
Minor
39
Minor
42
Minor
SD Series Reference Manual (x710 Mode)
Table 14. Event Codes
Description
Frequency not programmed.
Authorization fault detected.
The RF synthesizer is reporting an out-of-lock
condition.
The system is reporting that it has not been
calibrated. Factory calibration is required for proper
radio operation.
DSP download fault.
Receiver time-out. No data received within the
specified receiver time-out time.
Transmitter time-out detected.
Alarm test.
Unit address not programmed.
The DC input voltage approaching an
out-of-tolerance condition. If the voltage is too far out
of tolerance, operation may fail.
Output power not in valid range.
The transceiver's internal temperature is
approaching an out-of-tolerance condition. If the
temperature drifts outside of the recommended
operating range, system operation might fail.
Unexpectedly executing APP 1.
Unexpectedly executing APP 2.
Boot error. Active image unknown.
Reprogramming error.
41