Both setting and clearing of major/minor alarms and status conditions
are logged, as well as informational events (i.e., remote rebooted, repro-
gramming in process, etc.).

Major Alarms vs. Minor Alarms

Major Alarms report serious conditions that generally indicate a hard-
ware failure, or other abnormal condition that will prevent (or seriously
hamper) further operation of the transceiver. Major alarms generally
indicate the need for factory repair. Contact your factory representative
for further assistance.
Minor Alarms report conditions that, under most circumstances will not
prevent transceiver operation. This includes out-of-tolerance conditions,
baud rate mismatches, etc. The cause of these alarms should be investi-
gated and corrected to prevent system failure.

Status and Informational Events

Status events indicate current states or conditions that are not errors.
They are used merely to indicate process functions (i.e.,
).
in Process
Informational (Info) events pertain to those items which have occurred
since bootup. They may or may not indicate an error, and they do not
show current conditions, just an even that occurred at some point after
boot-up (i.e., Event #32

Event Code Definitions

Table 15 contains a listing of event codes that may be reported by the
transceiver. The codes shown are a subset of a larger pool of codes used
for various GE MDS products. For this reason, the table does not show
a sequential listing of all code numbers. Only the codes applicable to
this product series are shown.
Table 15. Event Codes
Event
Event
Code
Class
Description
000
Major
#0 Reserved
001
Major
Hardware mismatch.
002
Major
Frequency not programmed.
003
Major
Authorization fault detected.
004
Major
RF synthesizer out-of-lock condition.
005
Major
#5 Reserved
006
Major
A-to-D fault detected.
007
Major
Voltage regulator fault detected.
008
Major
Radio not calibrated. Factory calibration is required for proper
operation.
009
Major
DSP download fault.
SD Series Technical Manual
).
Booting Up
MDS 05-4846A01, Rev. D
Reprogramming