RX Tolerance
Loss of RX Data
Alarm Time
Save Configuration
Soft-Carrier Dekey
Radio Serial Number
Show Power
Settings
RX Signal-to-Noise
Ratio
36
RXTOL [NORMAL or CUSTOM]
The
command allows custom configuration of the receive toler-
RXTOL
ance, to improve performance with legacy radios (x790, x310, and so
on).
RXTOT [NONE, 1-1440]
The
command selects or shows the receive time-out timer value
RXTOT
in minutes. This timer triggers an alarm (event 12) if data is not detected
within the specified time.
Entering the
RXTOT
in minutes. Entering the
0 to 1440 resets the timer in minutes. (1440 minutes equals 24 hours.)
Entering the
RXTOT
timer.
SAVECONFIG
Saves a user configuration. Command is timed and aborts in 3 sec if no
response is provided.
SCD [0-255]
This command shows or changes the soft-carrier dekey delay in milli-
seconds.
This timer specifies how long to wait after the removal of the keying
signal before actually releasing the transmitter. A value of 0 millisec-
onds will unkey the transmitter immediately after the removal of the
keying signal.
SER
This command shows the radio's serial number as recorded at the fac-
tory (non-configurable).
SHOW [DC, PWR]
The
command shows different types of information based on the
SHOW
command variables. The different parameters are:
•
—Display DC input/output voltages
DC
•
—Display RF power output
PWR
SNR
This command continuously shows the signal-to-noise ratio of the
received signal expressed in dB, until you press the Enter key. As used
in this guide, the signal-to-noise measurement is based upon the signal
level following equalization, for received frames.
SD Series Reference Manual (x710 Mode)
command without a parameter shows the timer value
command with a parameter ranging from
RXTOT
command with the parameter
disables the
NONE
MDS 05-4670A01, Rev. E