Initialize EEPROM
Defaults
Initialization (for
standalone radio)
Initialization for P-20
Implementation
30
INIT
The
command is used to re-initialize the radio's operating parame-
INIT
ters to the factory defaults. This can be helpful when trying to resolve
configuration problems that might have resulted from the entry of one
or more improper command settings. If you are unsure of which com-
mand setting caused the problem, this command allows you to get back
to a known working state. The following changes to the radio are made
when
is entered:
INIT
•
is set to 0
CTS
•
is set to
DATAKEY
•
is set to
DEVICE
•
is set to 0
PTT
•
is set to 0
SCD
•
is set to 30 seconds and set to
TOT
•
is set to +37 dBm (5 watts)
PWR
All other commands remain as previously set.
INIT [SDx]
(Where "x" denotes SD radio model)
This command sets the transceiver for "normal" operation outside the
P-20 chassis by setting the following parameters to the values shown
below:
ASENSE
ACTIVE HI
AMASK
FFFF FFFF
RXTOT
NONE
Use this command to restore these three parameters to the standard
transceiver defaults if it was previously used in a P-20 package.
INIT [P-20]
This command sets the transceiver for service inside a P-20 redundant
chassis by setting the following parameters to the values shown below:
ASENSE
ACTIVE LO
AMASK
FFFF 0000
RXTOT
20
SD Series Reference Manual (x710 Mode)
ON
DCE
ON
(assert alarm output on all alarms)
(receive time-out timer disabled)
(trigger on major alarms)
(20 minute receive time-out timer)
MDS 05-4670A01, Rev. E