Init; Init [Sdx]; Init [P-20] - GE DS-SD4-1 Reference Manual

Table of Contents

Advertisement

Initialize EEPROM
Defaults
Initialization (for
standalone radio)
Initialization for P-20
Implementation
30

INIT

The
command is used to re-initialize the radio's operating parame-
INIT
ters to the factory defaults. This can be helpful when trying to resolve
configuration problems that might have resulted from the entry of one
or more improper command settings. If you are unsure of which com-
mand setting caused the problem, this command allows you to get back
to a known working state. The following changes to the radio are made
when
is entered:
INIT
is set to 0
CTS
is set to
DATAKEY
is set to
DEVICE
is set to 0
PTT
is set to 0
SCD
is set to 30 seconds and set to
TOT
is set to +37 dBm (5 watts)
PWR
All other commands remain as previously set.

INIT [SDx]

(Where "x" denotes SD radio model)
This command sets the transceiver for "normal" operation outside the
P-20 chassis by setting the following parameters to the values shown
below:
ASENSE
ACTIVE HI
AMASK
FFFF FFFF
RXTOT
NONE
Use this command to restore these three parameters to the standard
transceiver defaults if it was previously used in a P-20 package.

INIT [P-20]

This command sets the transceiver for service inside a P-20 redundant
chassis by setting the following parameters to the values shown below:
ASENSE
ACTIVE LO
AMASK
FFFF 0000
RXTOT
20
SD Series Reference Manual (x710 Mode)
ON
DCE
ON
(assert alarm output on all alarms)
(receive time-out timer disabled)
(trigger on major alarms)
(20 minute receive time-out timer)
MDS 05-4670A01, Rev. E

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mds sd series

Table of Contents