Alarm Status
Switched Carrier
TFTP Settings
Internal
Temperature
38

STAT

This command shows the current alarm status of the transceiver.
If no alarms exist, the message
If an alarm does exist, a two-digit code (00–31) is displayed and the
alarm is identified as "Major" or "Minor." A brief description of the
alarm code is also given.
If more than one alarm exists, the word
the screen, and additional alarms are viewed by pressing the
key. Detailed descriptions of event codes are provided in Table 14 on
Page 41.

SWC [ON, OFF]

How you configure this command is based on whether or not the trans-
ceiver is listening to a continuously keyed master. If the master is not
continuously keyed, then the master is operating in switched carrier
mode and the transceiver's SWC setting should be ON. If the master is
continuously keyed, the transceiver's SWC setting should be OFF. For
B modem operation only. SWC should be OFF for A modems.
NOTE:
must be set to
SWC

TFTP

Used to set/show all TFTP settings for upgrading the radio's firmware
through the Ethernet port using TFTP transfer. The command can be
used in several different ways:
TFTP HOST [ipaddr]
the firmware.
TFTP FILE [filename]
downloaded.
is used after the above commands to begin the TFTP
TFTP GET
transfer.
TFTP STATUS
load.

TEMP

This command shows the internal temperature of the transceiver in
degrees Celsius.
SD Series Reference Manual (x710 Mode)
NO ALARMS PRESENT
MORE
for switched carrier operation.
ON
sets the IP address of the TFTP server hosting
specifies the filename of the firmware to
can be used to check on the progress of the down-
appears.
appears at the bottom of
ENTER
MDS 05-4670A01, Rev. E