Dc Power Connection - GE DS-SD4-1 Reference Manual

Table of Contents

Advertisement

12
Table 3. Signal Loss in Coaxial Cables (at 400 MHz)
Cable Type
RG-8A/U
1/2 inch HELIAX
7/8 inch HELIAX
1-1/4 inch HELIAX
1-5/8 inch HELIAX
Table 4. Length vs. Loss in Coaxial Cables (at 900 MHz)
Cable Type
RG-8A/U
1/2 inch HELIAX
7/8 inch HELIAX
1-1/4 inch HELIAX
1-5/8 inch HELIAX

4.4 DC Power Connection

Power the transceiver from any well-filtered 10.0 to 30 Vdc power
source. The supply must be capable of providing at least 2.5 A of con-
tinuous current.
NOTE: Early SD4 models supported 10.5 to 16 Vdc power, not 10 to
30 Vdc. Check the labeling above the power connector to
confirm the operating range for your unit.
A power connector with screw terminals is provided with each unit (see
Figure 11). Strip the wire leads to 6 mm (1/4 inch) and insert in the wire
ports. Be sure to observe proper polarity as shown in Figure 11.
Figure 11. DC Power Connector (P/N 73-1194A39)
NOTE: The radio is designed for use in negative ground systems only.
SD Series Reference Manual (x710 Mode)
10 Feet
50 Feet
(3.05 Meters)
(15.24 Meters)
0.51 dB
2.53 dB
0.12 dB
0.76 dB
0.08 dB
0.42 dB
0.06 dB
0.31 dB
0.05 dB
0.26 dB
10 Feet
50 Feet
(3.05 Meters)
(15.24 Meters)
0.85 dB
4.27 dB
0.23 dB
1.15 dB
0.13 dB
0.64 dB
0.10 dB
0.48 dB
0.08 dB
0.40 dB
100 Feet
200 Feet
(30.48 Meters)
(60.96 Meters)
5.07 dB
10.14 dB
1.51 dB
3.02 dB
0.83 dB
1.66 dB
0.62 dB
1.24 dB
0.52 dB
1.04 dB
100 Feet
200 Feet
(30.48 Meters)
(60.96 Meters)
8.54 dB
17.08 dB
2.29 dB
4.58 dB
1.28 dB
2.56 dB
0.95 dB
1.90 dB
0.80 dB
1.60 dB
MDS 05-4670A01, Rev. E

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mds sd series

Table of Contents