Honda EG3600CX Manual page 144

Hide thumbs Also See for EG3600CX:
Table of Contents

Advertisement

82Z30000.book 3 ページ 2010年6月25日 金曜日 午後5時50分
STARTING SYSTEM TROUBLESHOOTING (CXS TYPE ONLY)
STARTER MOTOR DOES NOT OPERATE
Check the battery condition.
Normal
Check the battery voltage between the
starter motor side positive (+) battery cable
terminal and engine ground.
Normal
Check the continuity between BAT terminal
(White) and ST terminal (Black/white) of the
combination switch in the START position
(page 10-19).
Continuity
Check the fuse in the junction box.
Not blown
Check the starter solenoid (page 9-11).
Normal
Check for continuity between the junction box
terminals (page 10-20).
Normal
Disassemble the starter motor (page 9-10)
and check the each parts (page 9-11).
Abnormal
Replace with a known-good battery.
If the battery runs down again, perform the
CHARGING SYSTEM
TROUBLESHOOTING(page 7-7).
Low voltage
Replace battery positive (+) cable.
No continuity
Replace the combination switch (page 10-3).
Blown
Replace the blade fuse (page 10-3).
Abnormal
Replace the starter solenoid (page 9-10).
Abnormal
Replace the junction box (page 10-3).
STARTING SYSTEM
9-3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents